| Specification |
After-sales Service: Technical Support and Services;
Warranty: 24 Monthes;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: 50kg;
Type: Hydrostatic Test;
Maxcapacity: 400MPa;
Accuracy Grade: 0.5;
Load Way: Air Driven;
Loading Method: Air Compressor;
Display: Needle;
Control: Pressure Regulator Valve;
Weight: 0-100Kg;
Power Source: Pneumatic;
Oil Cylinder Position: Under;
Driven: Pneumatic;
Theory: Reciprocating Pump;
Function: Adjustable Pressure;
Pressure Source: Terek Fluid Booster Pump;
Application: Hydrostatic Test;
Structure: Stainless Steel Frame;
Usage: Liquid Pressurized and Testing;
Output Pressure: Pressure Adjustable;
Pressure Control: High Pressure Output Valve;
Driven Air Pressure Range: 3-8bar;
Diameter of Drive Plunger: 160mm;
Outlet Pressure Control: Drive Air Regulator Valve;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Transformer Test Bench;
Accuracy Grade: 0.5;
Display: LED;
Control: Manual Control;
Power Source: AC220V;
Function 1: Testing Turn Ratio;
Usage: Auto Testing Machine;
Function2: DC Resistance Test;
Function3: Power Frequency Withstand Voltage Test;
Function4: Induction Withstand Voltage Test;
Function5: 10kv No-Load Test;
Function6: 35kv No- Load Test;
Air Relative Humidity: <85%;
Transformer Ratio: 1--10000;
Max Test Current: 10A;
Product Name: Transformer Test Bench;
Model No: Hm5050;
Standard: IEC,GB;
Calibration Report: Factory Calibration Report or The Third Party Issu;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Impulse Voltage Generator;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Divider Ratio: 1000:1;
Output Waveform 1: 1.2μs/50μ;
Locking Range: More Than 20%;
Rated Nominal Voltage: 600kv;
Nominal Capacity: 30kj;
Levels of Voltage: 100kv;
Product Name: Impulse Voltage Generator;
Energy: 10kj, 15kj, 20kj,30kj,40kj,Ect;
Voltage: 100kv. 200kv,300kv, 400kv,600kv,800kv,etc;
Standard: IEC;
Certificated: ISO, CE;
Lead Time: 30~40 Workind Days;
Waveform: Lightning Waveform, Switching ,Chopped ,Ect;
Test Sample: Transformer, Circuit Breaker, Insulator;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Impulse Voltage Generator;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Divider Ratio: 1000:1;
Output Waveform 1: 1.2μS/50μ;
Locking Range: More Than 20%;
Rated Nominal Voltage: 600kv;
Nominal Capacity: 30kj;
Levels of Voltage: 100kv;
Product Name: Impulse Voltage Generator;
Energy: 10kj, 15kj, 20kj, 30kj, 40kj, Ect;
Voltage: 100kv. 200kv, 300kv, 400kv, 600kv, 800kv, etc;
Standard: IEC;
Certificated: ISO, CE;
Lead Time: 30~40 Workind Days;
Waveform: Lightning Waveform, Switching, Chopped, Ect;
Test Sample: Transformer, Circuit Breaker, Insulator;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Impulse Voltage Generator;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Divider Ratio: 1000:1;
Output Waveform 1: 1.2μs/50μ;
Locking Range: More Than 20%;
Rated Nominal Voltage: 600kv;
Nominal Capacity: 30kj;
Levels of Voltage: 100kv;
Product Name: Impulse Voltage Generator;
Energy: 10kj, 15kj, 20kj,30kj,40kj,Ect;
Voltage: 100kv. 200kv,300kv, 400kv,600kv,800kv,etc;
Standard: IEC;
Certificated: ISO, CE;
Lead Time: 30~40 Workind Days;
Waveform: Lightning Waveform, Switching ,Chopped ,Ect;
Test Sample: Transformer, Circuit Breaker, Insulator;
|