| Specification |
After-sales Service: 1. Answer Your Questions Within 00 Minutes During;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: New Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrograph;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
After-Sales Service: Online Technical Support;
Name: Atomic Absorption Spectrophotometer;
Wavelength Range: 190-900nm;
Wavelength Accuracy: 0.15nm;
Wavelength Reproducibility: 0.1nm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm;
|
After-sales Service: on Line Service;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectroscopic;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Model Number: Nb-5510;
Light Source: Lamp;
Wavelength Range: 190-700 Nm;
Spectral Bandwidth: 5 Nm;
Wavelength Accuracy: <= 0.2 Nm;
Wavelength Scanning: Multi-Wavelength Programming (10 Wavelength Ranges;
Cell Width: 4.5 mm;
Repeatability: Rsd < 0.5%;
Linearity: > 0.999;
Residual Cross-Contamination: 0.01%;
Sample Positions: 2*60 Positions, 1.8 Ml Vials;
Minimum Injection Volume: 0.1mu;L (250mu;L Standard Sample Pump);
Injection Pump: 100u;L, 250u;L (Standard), 1 Ml;
Sampling Loop Volumn: 100u;L (Standard), 20u;L, 50u;L, 200u;L (Options);
Switching Rate of Sampling Valve: 100 Ms;
|
After-sales Service: Online Support, Video Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectroscopic;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Model Number: AA4530f;
Size: 700X550X450mm;
Weight: 75kg;
Focal Length: 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm;
Measurement Range: 190 Nm -900 Nm;
Wavelength Repeatability: <=0.04nm;
Grating: 1800 Lines / mm;
|
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Prism Spectrometer;
Customized: Customized;
Optical System: Single Beam, Grating1200 Lines/mm;
Wavelength Range: 190~1100nm;
Wavelength Accuracy: 0.5nm;
Wavelength Repeatability: 0.3nm;
Baseline Flatness: 0.002A;
Photometric Mode: T, a, C, E;
Detector: Silicon Photodiode;
Light Source: Lamp, Tungsten Lamp;
Input: Membrane Keypad;
Display: TFT LCD;
|
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Prism Spectrometer;
Customized: Customized;
Optical System: Single Beam, Grating1200 Lines/mm;
Wavelength Range: 190~1100nm;
Wavelength Accuracy: 0.5nm;
Wavelength Repeatability: 0.3nm;
Baseline Flatness: 0.002A;
Photometric Mode: T, a, C, E;
Detector: Silicon Photodiode;
Light Source: Lamp, Tungsten Lamp;
Input: Membrane Keypad;
Display: TFT LCD;
|