| Specification |
Type: ±1.0% F.S.±0.5% F.S.;
Measuring Medium: Gas;
Accuracy Grade: 0.5G;
Pressure range: -100kpa...0~10kpa...60MPa;
IP Rating: IP54;
Customized: Customized;
Pressure Connection: G1/4, NPT1/4, R1/4, M12*1, M10*1, M20*1.5, G1/2;
Warranty: 1 Year;
Product Name: Digital Display Pressure Transmitter;
Material: Stainless Steel;
Output Signal: 4-20mA;0~10VDC;RS485;
Power Supply: 12~30VDC;
Customized Support: OEM, ODM, Obm;
Accuracy: ±1.0% F.S.±0.5% F.S.;
Electronic Connection: Big Hirschmann;
Protection Class: IP54;
Medium: Gas, Liquid;
Workingtemperature: -20~75℃;
|
Pressure range: 4 bar;
Pressure Reference: Vented gage;
Operating temperature range: -40 ℃ to 125 ℃;
Storage temperature range: -40 ℃ to 125℃;
Compensated temperature range: -40 ℃ to 125 ℃;
Electrical Connector Type: Cable harness, 3 meter cable length;
Pressure Port Type: G1/8 (ISO 1179-3);
Output Transfer Function: Regulated: 0.5 Vdc to 4.5 Vdc;
Supply current (typ.): 5.5 mA;
Accuracy: ±0.25 %FSS;
|
Pressure range: 16 Bar;
Pressure Reference: Sealed gage;
Operating temperature range: -40 ℃ to 125 ℃;
Storage temperature range: -40 ℃ to 125℃;
Compensated temperature range: -40 ℃ to 125 ℃;
Electrical Connector Type: Metri-Pack 150, Standard (UL 94 H);
Pressure Port Type: G1/4 (ISO 1179-3);
Output Transfer Function: Current: 4 mA to 20 mA;
Accuracy: ±0.25 %FSS;
|
Type: Normal Pressure Transmitter;
Structure Type: Diffused Silicon Pressure Transmitter;
Measuring Medium: All;
Accuracy Grade: 0.5%F.S;
Pressure range: 0.001MPa~35MPa;
IP Rating: IP65;
Customized: Customized;
Power Supply: 12-36VDC;
Output Signal: 4~20mA, 1~5V, 0~10V, RS485;
Measuring Range: -0.1...0..100MPa;
Medium Temperature: -40~200 C;
Measuring Media: Gaseous, Liquid, Water;
Pressure Type: Gauge Pressure, Absolute Pressure;
Installation Mode: M20*1.5(Thread), 1/2 NPT, G 1/2, Others;
|
Type: Normal Pressure Transmitter;
Structure Type: Diffused Silicon Pressure Transmitter;
Measuring Medium: Stream, Gas, Liquid;
Accuracy Grade: 0.5G;
Pressure range: 0~0.5…10mh2o;
IP Rating: IP68;
Customized: Customized;
Overload: 1.5 Times Pressure Range of Full Scale;
Accuracy: ±0.5%Fs;
Long-Term Stability: ±0.25%Fs/Year;
Output: RS485;
Power Supply: 3.0~8.0 VDC;
Standby Current: <5ua;
Date Collection Cycle: 0~65535s;
Power Consumption: About 200ua with Data Collection Cycle as 1s;
Power Consumption(Others): About 70ua with Data Collection Cycle as 3s;
Power Consumption(Others2): About 50ua with Data Collection Cycle as 5s;
Power Consumption(Note): Longer Data Collection Cycle, Lower Consumption;
Medium Temperature: -40~85℃;
|