| Specification |
Installation Type: Wall-Mounted Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog or Digital Output;
Production Process: Integration;
Material: Carbon Humidity;
Measuring Medium: Temperature and Humidity;
IP Rating: IP65;
Customized: Customized;
Product name: Wireless Temperature And Humidity Data Logger;
Range: 0-100%RH, -20-70℃;
Temperature measurement accuracy: 0-100%RH, -40-100℃;
Power supply: 5V;
Temperature accuracy: ±2%RH/±1.5%RH;
Operation method: Button;
Data export interface: USB/RS485;
Display method: Segment LCD;
Number of channels: 1-4 road;
Battery standby current: 500uA;
|
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Zirconia Battery Electrodes;
Material: Ceramics;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Temperature Range: 1200-1750;
Oxygen Activity: 1~1500ppm;
Oxygen Electromotive: -300, +300mv;
Response Time: 3s-8s;
Measured Rate: 98%;
|
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Zirconia Battery Electrodes;
Material: Ceramics;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Temperature Range: 1200-1750;
Oxygen Activity: 1~1500ppm;
Oxygen Electromotive: -300, +300mv;
Response Time: 3s-8s;
Measured Rate: 98%;
|
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Integration;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Measuring Time: 3~5 Seconds;
Index No: Kb / Kw / Ks / Hr / or / More Models;
Allowable Error: Normal Grade (P) Plus or Minus 5 Degrees Celsius;
Measuring Range: 0 to 2000 Degrees Celsius;
|
Installation Type: Thread or Flange Connection;
Sensing Type: PT100 Explosion-Proof Temperature Sensor;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: PT100 Explosion-Proof Temperature Sensor;
Material: Stainless Steel;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Input Signal 1: Thermocouple: K, E, S, B, J, T, R, ....;
Input Signal 2: Rtd: PT100, PT1000;
Temperature Range: -200 - 600 Deg.C;
Power Supply: DC 10-30V;
Output Signal: 4-20mA, 0-10V, 0-5V, 4-20mA+Hart, RS 485 Mod_Bus;
Accuracy: 0.5%F.S.;
Sensitive Element: PT 100;
Long-Term Stability: 0.2%F.S. / Y;
Response Time: 30s;
Temperature Drift: 0.2%F.S./ Deg.C;
Insert Diameter: 12mm (Other Can Be Customized);
Explosion-Proof: Intrinsically Safe Exia II Bt4;
Protection: IP 65;
Display Range: -1999-9999;
Display: LED / LCD Display;
|