| Specification |
After-sales Service: Lifetime Technical Support;
Warranty: 1 Year for Transformer CT PT Tester;
Type: CT Meter Transformer CT PT Tester;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Manual Control;
Weight: 15kg;
Power Source: AC220V;
Product Name: Current Power Transformer Tester CT PT Analyzer;
Usage: Transformer CT PT Test;
Test Standards: IEC60044-1/2/5/6;
Voltage Output: 0.1~180V (AC);
Current Output: 0.001~5A(RMS);
Maximum Knee Voltage: 45kv;
Power Supply: 220V 50Hz;
Current Measurement Range: 0~10A;
Secondary Current: 1A,3A,5A;
Power Output: 500va;
|
After-sales Service: Life Long Support;
Warranty: 1 Year or Extend;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.0;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 1000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Long Support;
Warranty: 1 Year or Extend;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Touch Screen;
Power Source: 220V/380V ±10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
Control: Computer Control;
Weight: 150kg;
Power Source: AC220V;
Product Name: Partial Discharge Testing Equipment;
Rated Capacity: 5-1000kVA;
Output Voltage: 0~1000kv;
Output Voltage Waveform: Power Frequency, Sine Wave;
Partial Discharge: Under Rated Voltage<5PC;
Surface Temperature: Oil Immersed:<55℃ Gas: <50℃;
Insulation Method: Oil, Gas;
No-Load Loss: 0.2%-0.3%;
|
After-sales Service: One Year;
Warranty: 1 Year;
Accuracy Grade: 1.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Rated Nominal Voltage: 300kv or Customized;
Rated Voltage: 100kv or Customized;
Rated Energy: 15kj or Customized;
Total Impulse Capactiance: 3UF;
Single-Stage Impulse Capacitor: 1.μf/100kv;
Load Capacitance: 500~3000PF;
Amplitude Adjusts Error: Less Than 1%;
Synchronous Malfunction Rate: Less Than 1%;
Waveform: Standard Lightning Impact Waveform,Standard Operat;
Standard: IEC;
|