| Specification |
Type: Fire Alarm Host;
Function: GSM Function;
Usage: Fire, Smoke, Factory/Hotel/School/Office Fire Alarm Control;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: GSM Dial-up;
Wiring Mode: Bus System;
Zones: 1-32;
Power Supply: 110VAC/240VAC;
Battery: 12V2ah*2;
Fire Relay Output: Nc and No;
Fault Relay Output: Nc and No;
Sounder Output: 2 Circuits;
Zone/Detector: Maximumly Supports 20PCS;
Supply Type: R&D Manufacturer;
OEM & ODM Service: Available;
Application: Hotel, School, Super Market, Apartment etc.;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: Alarm;
Receive Frequency: 485/232;
Wiring Mode: Sub-Line System;
Weight: 7kg;
Color: Red;
Number of Zones: 4;
Primary AC: 90-270VAC 50/60Hz;
Standby Battery: 2*12V;
Power Supply Rating: 3 AMPS @24VDC;
Alarm&Fault Relay Rating: 2A & 30VAC , Resistive;
Normal Initiating Operating Voltage: 23VDC, Maximum 26VDC, Regulated;
Maximum Number of Detectors: 30;
Sounder Voltage(VDC): 27;
Maximum Sound Current Per Zone: 500mA;
Max. Sounder Sounder Number of Per Zone: 5;
Alarm Zone End of Line(Ohms): 10K;
Max. Auxiliary Supply Current (Ma): 500mA;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: Alarm;
Wiring Mode: Sub-Line System;
Weight: 2.7kg;
Number of Zones: 2;
Primary AC: 90-270VDC;
Standby Battery: DC 12V/2.2ah * 2 (Not Include);
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: Dial-up;
Receive Frequency: Wire;
Wiring Mode: Sub-Line System;
Main Supply: 90-270VAC, 50/60 Hz;
Number of System Zones: 4 Zone;
Panel Weight: 5kg;
Extinguishant Release Output: 21V-28VDC. Maximum Load 2 AMP;
Alarm Zone End of Line (Ohms): 10K;
Power Supply Rating: 3 AMPS Total Including Battery Charge 28V+/-2V;
Battery Type: Two 12 Volt Sealed Lead Acid in Series;
Battery Charge Voltage: 27.6VDC Nominal;
Battery Charge Current: 0.7A Maximum;
Maximum Current Draw From Battery: 3AMPS;
Fault Relay Contact Rating: 2A /30VDC Maximum for Each;
Fire Relay Contact Rating: 2A /30VDC Maximum for Each;
First Stage Contact Rating: 2A /30VDC Maximum for Each;
Second Stage Contact Rating: 2A /30VDC Maximum for Each;
Extract Contact Rating: 2A /30VDC Maximum for Each;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: Dial-up;
Receive Frequency: Wire;
Wiring Mode: Sub-Line System;
Main Supply: 90-270VAC, 50/60 Hz;
Number of System Zones: 4 Zone;
Panel Weight: 5kg;
Extinguishant Release Output: 21V-28VDC. Maximum Load 2 AMP;
Alarm Zone End of Line (Ohms): 10K;
Power Supply Rating: 3 AMPS Total Including Battery Charge 28V+/-2V;
Battery Type: Two 12 Volt Sealed Lead Acid in Series;
Battery Charge Voltage: 27.6VDC Nominal;
Battery Charge Current: 0.7A Maximum;
Maximum Current Draw From Battery: 3AMPS;
Fault Relay Contact Rating: 2A /30VDC Maximum for Each;
Fire Relay Contact Rating: 2A /30VDC Maximum for Each;
First Stage Contact Rating: 2A /30VDC Maximum for Each;
Second Stage Contact Rating: 2A /30VDC Maximum for Each;
Extract Contact Rating: 2A /30VDC Maximum for Each;
|