| Specification |
After-sales Service: One Year Warranty;
|
After-sales Service: Provided;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Features: Ultra-High Sensitivity Detector; Ultra-Low Noise;
Interface: USB 2.0;
Integration Time: 4ms - 120s;
Work Humidity: < 95%;
Weight: 390g;
|
After-sales Service: 1 Year;
Application: Jewelry Shop;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Detection Limit: 100ppm Best Substance Effect;
Precision: ±10ppm~0.2%;
Detector: Gas Proportional Detector;
Testable Elements: Au, AG, Cu, Zn, Ni, PT, Pd;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Monochromator: Aberration-Corrected Czerny-Tumer Type Monochromat;
Wavelength Range: 185nm~910nm, Automatic Adjustment;
Raster Line Density: 1800 Lines/mm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm, Five Levels with Automa;
Wavelength Indication Error: ±0.10nm;
Wavelength Repeatability Accuracy: Better Than 0.05nm;
Resolution: Better Than 0.3nm;
Baseline Drift: ±0.002ABS/30min;
Flame Atomizer Method: Flame, Graphite Furnace;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Monochromator: Aberration-Corrected Czerny-Tumer Type Monochromat;
Wavelength Range: 185nm~910nm, Automatic Adjustment;
Raster Line Density: 1800 Lines/mm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm, Five Levels with Automa;
Wavelength Indication Error: ±0.10nm;
Wavelength Repeatability Accuracy: Better Than 0.05nm;
Resolution: Better Than 0.3nm;
Baseline Drift: ±0.002ABS/30min;
Flame Atomizer Method: Flame, Graphite Furnace;
|