| Specification |
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Security Alarm Host;
Function: Networked;
Usage: Door, Auto, Personal, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥110dB;
Networking Mode: TCP/IP;
Receive Frequency: 24.00~24.25GHz;
Wiring Mode: Sub-Line System;
Identify The Target: Small Animals, People, Vehicles;
Recognition Speed: 0.5m/S~30m/S;
Distance Measurement Range: Radius 1.5~500m;
Measuring Range: Radius 1.5~700m;
Distance Resolution: 1.5m;
Coverage Angle: 360 Degrees;
Alarm Record Playback: Support Alarm Record Playback, Custom Combination;
Data Flow: Analysis Data with Target Position and Speed;
Installation Height: Radar ≥3meter, Ball Camera ≥3metereter;
Power Consumption: AC220V\125W;
Radar System: Fmcw (Frequency Modulated Continuous Wave);
Radar Target Data: Distance, Direction, Angle;
Detection Distance: 360 Degrees, 500 Meters;
Resolution: 1920*1080;
Number of Cores: GPU 384 Cores, CPU 6 Cores;
|
Type: Fire Alarm Host;
Usage: Fire, Smoke;
Material: ABS;
|
Type: Wireless Alarm Host;
Function: Non-Networked;
Usage: Door, Auto, Personal, Window, Fire;
Alarm Volume (within 1m): ≥110dB;
Networking Mode: GSM Dial-up;
Receive Frequency: 315MHz;
Wiring Mode: Sub-Line System;
One-Key-Control: All The Settings Can Be Finished by Keypad;
Language: Italian, Spanish, French, and Other Languages Avai;
Screen: LCD Screen with Time Clock Display;
Input Voltage: DC12V/1A;
Standby Current: <55mA;
GSM Frequency: 900/ 1800/ 1900MHz;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: Alarm;
Receive Frequency: 485/232;
Wiring Mode: Sub-Line System;
Weight [Without Battery ]: 3kg;
Number of Zones: 2;
Primary AC: 90-270VDC;
Standby Battery: 2*12V;
Detector Voltage(VDC): 24VDC;
Maximum Number of Detectors Per Zone: 30;
|