| Specification |
After-sales Service: Free Parts Replacement Within a Year;
Warranty: 12 Months After Delivery;
Accuracy: 0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Volume Type Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Twin-Screw Principle;
Measurement Object: Closed Pipeline;
Measurement Error: 0.1%;
Repeatability: 0.02%;
Product Design Life: 10 Years;
Viscosity Range: 0.2-1000cst;
Flange: DN50;
|
After-sales Service: Maintain;
Warranty: 1year;
Accuracy: ±0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas;
Size: DN15 (½") to DN1200 (48");
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Brand Name: Endress+Hauser;
Place of Origin: Switzerland;
Measurement Range: 5m;
Medium: Water;
Liquid Range: 5m or 8m;
Precision Accuracy: ±3 mm or 0.2%;
Connectivity: Flange;
Customized Support: OEM, ODM, Obm;
Resolution Ratio: 1mm;
Power Supply: 24VDC (Standard); 220VAC (Optional);
Flow Measurement Range: 0.1~10 M/S;
Ambient Temperature: -25~+60°c;
Temperature Effects: ±0.1% Fs/10K;
Power Supply Voltage: 24VDC;
Output Signal: 4-20mA+Hart;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN15-2000;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Karman Vortex Street;
Measurement Object: Closed Pipeline;
|
After-sales Service: on Line;
Warranty: 12 Months;
Accuracy: 0.1-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: < DN5;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Open Channel;
Product Name: Coriolis Mass Flowmeter for CNG Dispenser with Ate;
Key Word: Mass Flow Meter;
Measurement Method: Directly Measure Mass Flow;
Measurement Accuracy Affected Factor: Only by Vibration;
Special Medium: Gases with Minimal Liquid Content;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow;
Installation Requirements: No Need to Consider Upstream and Downstream;
Measurable Medium: High-Viscosity , Liquids with Trace Solids;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Measurement Object: Pipes, Channels, Natural Streams, Rivers;
Flow Rate Measurement Range: 0 - 10.00 M/S, -5 - 5.00 M/S (for Bidirectional FL;
Flow Rate Accuracy: 1% ± 0.01 M/S; Resolution: 0.001 M/S;
Water Level Range: 0-10m; (Can Be Specially Customized);
Waterproof Rating: Sensor IP68, Host IP65 (IP68 Can Be Specially Cust;
Output Interface: RS485, Modbus, RTU;
|